Pocket 30 CFR

ElkoLocal · Mine safety

Pocket 30 CFR

The mining regulations, searchable from your pocket. Type a citation (56.14107) or plain words ("guarding conveyor", "fall protection").

  •  sections
  • 10parts
  •  eCFR sync
  • Offlinecapable
Mine type

Loading regulations…

Install

Common lookups

From real MSHA inspection data

Most-cited in Nevada

The rules MSHA inspectors wrote up most often at Nevada metal and nonmetal mines in the last 12 months. Tap one to read it.

2,224 citations & orders at 158 mines
  1. 1 § 57.3360Ground support use 139cited
  2. 2 § 56.14107Moving machine parts 99cited
  3. 3 § 56.14100Safety defects; examination, correction and records 93cited
  4. 4 § 56.20003Housekeeping 79cited
  5. 5 § 56.14112Construction and maintenance of guards 59cited
  6. 6 § 57.4102Spillage and leakage 56cited
  7. 7 § 57.14100Safety defects; examination, correction and records 55cited
  8. 8 § 56.4102Spillage and leakage 53cited
  9. 9 § 47.41Requirement for container labels 52cited
  10. 10 § 57.20003Housekeeping 52cited
  11. 11 § 56.12028Testing grounding systems 51cited
  12. 12 § 56.12004Electrical conductors 44cited
  13. 13 § 56.4201Inspection 42cited
  14. 14 § 56.14207Parking procedures for unattended equipment 41cited
  15. 15 § 56.4104Combustible waste 41cited

Source: MSHA Open Government Data (Violations and Mines data sets, file dated Nov 13, 2026). Citations and orders issued Nov 13, 2025 – Nov 12, 2026 at mines in Nevada classed metal/nonmetal; vacated ones left out; counted by section. 2,224 in all. MSHA data sets

Quick-reference cards

One screen each. Print one or save it as a PDF for the truck, the crib room or a toolbox talk.

Pocket 30 CFR · Quick card

Workplace exams

Every working place, every shift, before work starts.

1Who and when

2What to do

  • Look for conditions that may adversely affect safety or health.§ 56.18002
  • Promptly tell miners in affected areas and start corrective action.§ 56.18002
  • Possible imminent danger: tell the operator immediately; everyone is withdrawn until it is fixed.§ 56.18002

3Record it

  • Before the end of the shift: examiner's name, date, areas examined, each adverse condition found.§ 56.18002
  • Add the date of the corrective action once the condition is fixed.§ 56.18002
  • Keep records at least one year; MSHA and miners' representatives can inspect them and get copies.§ 56.18002

Informal summary, not legal advice and not the full rule. Read the cited sections in 30 CFR (www.ecfr.gov) and follow your mine's procedures.

Pocket 30 CFR · Quick card

Lockout / tagout

Power off, locked out and blocked before you work on it.

1Before the work

  • De-energize electrically powered equipment before mechanical work.§ 56.12016 § 57.12016
  • Lock out the power switch (or other measures) so nobody can energize it without your knowledge.§ 56.12016
  • Post a warning notice at the switch, signed by the people doing the work.§ 56.12016
  • Block machinery against hazardous motion before repairs or maintenance.§ 56.14105 § 57.14105

2Power circuits

3Testing and removal

  • Motion or power only for adjustments or tests that cannot be done without it, with people effectively protected.§ 56.14105
  • Only the person who installed the lock, or authorized personnel, removes it.§ 56.12016 § 56.12017

Informal summary, not legal advice and not the full rule. Read the cited sections in 30 CFR (www.ecfr.gov) and follow your mine's procedures.

Pocket 30 CFR · Quick card

Ground control

Examine it, scale or support it, keep people out until it is safe.

1Examine

  • Operator designates people experienced in examining and testing for loose ground.§ 56.3401 § 57.3401
  • Examine before work starts, after blasting, and as conditions warrant during the shift.§ 56.3401 § 57.3401
  • Highwalls and banks next to travelways (and underground haulageways and travelways): at least weekly.§ 56.3401 § 57.3401

2Correct

3Design

  • Surface: mining methods must keep walls, banks and slopes stable where people work or travel.§ 56.3130
  • Underground: use ground support where conditions or experience show it is needed, and maintain it.§ 57.3360

Informal summary, not legal advice and not the full rule. Read the cited sections in 30 CFR (www.ecfr.gov) and follow your mine's procedures.

Pocket 30 CFR · Quick card

Berms & haul roads

Mid-axle berms, clean roads, controlled speeds.

1Berms and dump points

  • Berms or guardrails on roadway banks where a drop-off could overturn a vehicle or endanger people.§ 56.9300 § 57.9300
  • At least mid-axle height of the largest self-propelled equipment that usually uses the road.§ 56.9300
  • Berms, bumper blocks or similar devices at dump points where overtravel or overturning is a hazard.§ 56.9301 § 57.9301

2Roads and traffic

3Parking

  • Unattended equipment: controls in park, parking brake set; on a grade, chock or turn into a bank.§ 56.14207 § 57.14207

Informal summary, not legal advice and not the full rule. Read the cited sections in 30 CFR (www.ecfr.gov) and follow your mine's procedures.

Pocket 30 CFR · Quick card

Fall protection

Tie off where you could fall; keep access, rails and openings safe.

1Tie off

2Access and edges

Informal summary, not legal advice and not the full rule. Read the cited sections in 30 CFR (www.ecfr.gov) and follow your mine's procedures.

Quick access

Tap a topic to read it here, or jump to the official text.

What it means on the job

Plain-English notes on the most-cited rules. They also appear above the official text when you open one of these sections.

Informal guidance, not legal advice. The regulation text is the rule.

  • Guard moving machine parts

    Any moving part that could catch, pull in or crush a person has to be guarded: gears, sprockets, chains, drive, head, tail and take-up pulleys, flywheels, couplings, shafts, fan blades and similar parts. The only exception in this section is for parts at least 7 feet away from walking or working surfaces. On the job, look at each pinch point from anywhere a person could stand or reach, not just from the front.

    § 56.14107 § 57.14107

  • Guards that stay on and hold up

    Guards must be built and maintained to handle the machine's vibration, shock and wear, and must not create a hazard themselves. They have to be securely in place whenever the machinery is running. The only exception is testing or adjusting that cannot be done with the guard on.

    § 56.14112 § 57.14112

  • Pre-shift checks and safety defects

    The operator of self-propelled mobile equipment must inspect it before using it on each shift. Safety defects on any equipment, machinery or tools must be fixed in a timely manner. If a defect makes it unsafe to keep using, take it out of service: park it in an area posted for that, or tag or mark it so nobody uses it until it is fixed. Safety defects on mobile equipment that are not fixed right away must be reported to and recorded by the mine operator, and the record kept until the repair is made.

    § 56.14100 § 57.14100

  • Housekeeping

    Keep workplaces, passageways, storerooms and service rooms clean and orderly. Floors must be kept clean and, as far as possible, dry; where wet processes are used, keep drainage working and provide dry places to stand where practicable. Floors and walkways must be kept free of protruding nails, splinters, holes and loose boards, as practicable.

    § 56.20003 § 57.20003

  • Fuel and oil spills and leaks

    Flammable or combustible liquid that spills or leaks, such as fuel, oil or hydraulic fluid, has to be cleaned up in a timely manner or controlled so it cannot become a fire hazard.

    § 56.4102 § 57.4102

  • Combustible waste

    Do not let waste, including liquids, build up to the point it could create a fire hazard. Until it is disposed of properly, waste or rags with flammable or combustible liquid on them go in covered metal containers. On the surface, other containers that will contain a flame are also allowed; underground (57.4104), only covered metal containers.

    § 56.4104 § 57.4104

  • Fire extinguisher and fire system inspections

    Fire extinguishers get a visual check at least once a month to confirm they are charged and operable, a maintenance check at least every 12 months, and hydrostatic tests on the required schedule. Fire hoses, hydrants, valves and water lines get a visual inspection at least every 3 months and a use test every 12 months; fire suppression systems are inspected at least every 12 months. Whoever does each inspection or test certifies it with the date. Hydrostatic test certifications are kept until the extinguisher is retested or retired; the others are kept for one year.

    § 56.4201 § 57.4201

  • Electrical conductors

    Wires and cables must be big enough that normal current does not heat them enough to damage their insulation. Where conductors could be damaged mechanically, for example run over, pinched, rubbed or struck, they must be protected.

    § 56.12004 § 57.12004

  • Cable fittings and bushings

    Where power wires and cables pass into or out of electrical compartments they must be adequately insulated. Cables may enter metal frames of motors, splice boxes and electrical compartments only through proper fittings, and insulated wires other than cables that pass through metal frames need insulated bushings in the holes.

    § 56.12008 § 57.12008

  • Lock out before mechanical work

    Before mechanical work on electrically powered equipment, de-energize it and lock out the power switch, or take other measures, so nobody can turn it back on without the people working on it knowing. Post a warning notice at the power switch, signed by the people doing the work. Only the person who installed the lock or device, or authorized personnel, may remove it.

    § 56.12016 § 57.12016

  • Test grounding systems

    Test the continuity and resistance of grounding systems right after they are installed, repaired or modified, and at least once a year after that. Keep the resistance reading from the most recent test available for MSHA on request.

    § 56.12028 § 57.12028

  • Electrical covers in place

    Inspection and cover plates on electrical equipment and junction boxes have to stay in place at all times, except while testing or repairing.

    § 56.12032 § 57.12032

  • Safe access

    Every working place needs a safe way to get to it, and that access has to be maintained. In practice that means sound ladders, stairs, walkways and platforms that are kept in good shape and clear.

    § 56.11001 § 57.11001

  • Horns and backup alarms

    Horns and other audible warning devices provided on self-propelled mobile equipment must work. If the operator's view to the rear is obstructed, the machine needs an automatic reverse alarm, a wheel-mounted bell alarm, a discriminating backup alarm that covers the blind area, or an observer who signals when it is safe to back up. Alarms must be audible above the surrounding noise; at night an automatic reverse-activated strobe light may be used instead of an audible alarm. Rail equipment is not covered.

    § 56.14132 § 57.14132

  • Parking unattended equipment

    Never leave mobile equipment unattended unless the controls are in the park position and the parking brake, if it has one, is set. When parked on a grade, also chock the wheels or tracks or turn them into a bank (or a rib, underground).

    § 56.14207 § 57.14207

  • Berms and guardrails

    Where a road has a drop-off steep or deep enough to overturn a vehicle or endanger people in equipment, berms or guardrails must be provided and maintained on the bank. They must be at least mid-axle height of the largest self-propelled mobile equipment that usually travels that road. Openings are allowed only as needed for drainage. A narrow exception covers elevated roads used infrequently and only by service or maintenance vehicles, and only when every condition in paragraph (d) is met.

    § 56.9300 § 57.9300

  • Roadway maintenance

    Water, debris or spilled material on a roadway that creates a hazard to operating mobile equipment has to be removed.

    § 56.9313 § 57.9313

  • Workplace examinations

    A competent person designated by the operator must examine each working place at least once each shift, before miners begin work there, for conditions that could hurt safety or health. Miners in affected areas must be told promptly and corrective action started; anything that may be an imminent danger goes to the operator immediately and people are withdrawn until it is fixed. Before the end of the shift, record who did the exam, the date, the areas examined and each adverse condition found, then add the date of the fix once it is corrected. Keep the records for at least one year.

    § 56.18002 § 57.18002

  • Fall protection

    Wear a safety belt and line wherever there is a danger of falling; today that usually means a full-body harness and lanyard tied off to a suitable anchor. When anyone enters a bin, tank or other dangerous area, a second person must tend the lifeline.

    § 56.15005 § 57.15005

  • Ground support underground

    Ground support must be used wherever ground conditions, or experience in similar ground in the mine, show it is needed. When it is needed, the support system has to be designed, installed and maintained to control the ground where people work or travel. Damaged, loosened or dislodged timber support that creates a hazard must be repaired or replaced before anyone works or travels in that area.

    § 57.3360

  • Examine ground conditions

    The mine operator designates people experienced in examining and testing for loose ground. They examine, and test where applicable, the ground where work will be done before work starts, after blasting, and as conditions warrant during the shift. Highwalls and banks next to travelways (and, underground, haulageways and travelways) are examined at least weekly, or more often if conditions are changing.

    § 56.3401 § 57.3401

  • Escape routes

    Escape routes must be inspected at regular intervals, kept in safe, travelable condition, and marked with conspicuous, easy-to-read signs that clearly show the way out.

    § 57.11051

  • HazCom container labels

    Every container of a hazardous chemical needs a label; a tag or marking with the right information counts. Replace a label right away if it is missing or unreadable, and never remove or deface one. For chemicals made at the mine, the operator prepares the label and updates it within 3 months of learning significant new hazard information.

    § 47.41

  • Quarterly employment report

    Every mine where anyone worked during a calendar quarter must file MSHA Form 7000-2 within 15 days after the quarter ends. Keep a copy at the mine office nearest the mine for 5 years.

    § 50.30

  • Part 46 training plan

    You need a written training plan, approved by MSHA, that covers new miner, newly hired experienced miner, new task, annual refresher and site-specific hazard awareness training.

    § 46.3

  • New miner training (Part 46)

    New miners need at least 24 hours of training: at least 4 hours before they start work, more within 60 days, and the rest within 90 days. Until they finish, they must work where an experienced miner can see that they are working safely. Training completed under Part 46 or Part 48 within the last 36 months may count; see paragraphs (f) and (g).

    § 46.5

  • New task training (Part 46)

    Before a miner does a task they have no experience in, train them on its health and safety aspects and safe work procedures, including chemical hazards and the mine's HazCom program. Train again when a change in the task affects its risks. It is not required when the miner has done similar work and you observe that they can do it safely.

    § 46.7

  • Annual refresher (Part 46)

    Each miner needs at least 8 hours of annual refresher training, no later than 12 months after the last one. It must cover changes at the mine that could affect health or safety, plus other health and safety subjects relevant to the mine.

    § 46.8

  • Training records (Part 46)

    Record and certify each training on MSHA Form 5000-23 or a form with the same information, by the deadlines in paragraph (c), and give the miner a copy when paragraph (d) calls for it. False certification is punishable under the Mine Act.

    § 46.9

  • Site-specific hazard awareness

    Before people who are not miners, such as office staff, delivery drivers, customers, vendors, visitors and some contractors, are exposed to mine hazards, give them site-specific hazard awareness training: the hazards at this mine and its emergency procedures. Miners such as drillers or blasters who move between mines need it at each mine. It is not required for someone who is accompanied at all times by an experienced miner who knows the site.

    § 46.11

  • Part 48 training plan

    Each operator must have a training plan approved by the MSHA District Manager, with the information this section lists, and must train miners according to it.

    § 48.23

  • New surface miner training (Part 48)

    New surface miners need at least 24 hours of training, generally before they are assigned work duties. The District Manager may allow part of it after assignment, but at least 8 hours, covering the work environment, hazard recognition and the health and safety aspects of their tasks, always comes first, with the rest within 60 days.

    § 48.25

  • New underground miner training

    New underground miners need at least 40 hours of training before they are assigned work duties, given in conditions as close as practicable to actual underground conditions, with about 8 hours at the mine site.

    § 48.5

  • Annual refresher (Part 48)

    Each miner needs at least 8 hours of annual refresher training covering the subjects this section lists (48.8 for underground miners, 48.28 for surface miners).

    § 48.8 § 48.28

  • Experienced miner training (Part 48)

    Experienced miners who are newly hired, transferred, or returning after more than 12 months away must finish this training before they begin work duties. Anyone returning to mining after 5 years or more gets at least 8 hours.

    § 48.26 § 48.6

What changed

Sections the official eCFR shows as amended in the last year. We check eCFR every day; updated sections carry a badge everywhere on this page.

Amendment dates from the eCFR versioner API, last checked Nov 20, 2026 5:50 pm PST.

Get change alerts

One short email when a 30 CFR section for your mine type is amended. No spam, unsubscribe any time.

Alerts for: all parts

We send a confirmation link first (double opt-in). Your address is only used for these alerts.

Browse by part

Title 30, Chapter I — Mine Safety and Health Administration, Department of Labor

Part 46 · Training · surface Training and Retraining of Miners Engaged in Shell Dredging or Employed at Sand, Gravel, Surface Stone, Surface Clay, Colloidal Phosphate, or Surface Limestone Mines
Part 47 · HazCom Hazard Communication (HazCom) 9 subparts

Part 47 on eCFR

Subpart A Purpose, Scope, Applicability, and Initial Miner Training 2
Subpart B Definitions 1
Subpart C Hazard Determination 1
Subpart D HazCom Program 2
Subpart E Container Labels and Other Forms of Warning 4
Subpart F Material Safety Data Sheets (MSDS) 5
Subpart H Making HazCom Information Available 3
Subpart I Trade Secret Hazardous Chemical 7
Subpart J Exemptions 2
Part 48 · Training Training and Retraining of Miners 2 subparts

Part 48 on eCFR

Subpart A Training and Retraining of Underground Miners 12
Subpart B Training and Retraining of Miners Working at Surface Mines and Surface Areas of Underground Mines 12
Part 49 · Mine rescue Mine Rescue Teams 2 subparts

Part 49 on eCFR

Subpart A Mine Rescue Teams for Underground Metal and Nonmetal Mines 9
Subpart B Mine Rescue Teams for Underground Coal Mines 14
Part 50 · Reporting Notification, Investigation, Reports and Records of Accidents, Injuries, Illnesses, Employment, and Coal Production in Mines 5 subparts

Part 50 on eCFR

Subpart A General 2
Subpart B Notification, Investigation, Preservation of Evidence 3
Subpart C Reporting of Accidents, Injuries, and Illnesses 8
Subpart D Quarterly Employment and Coal Production Report 2
Subpart E Maintenance of Records; Verification of Information 2
Part 56 · Surface M/NM Safety and Health Standards—Surface Metal and Nonmetal Mines 19 subparts

Part 56 on eCFR

Subpart A General 3
Subpart B Ground Control 10
Subpart C Fire Prevention and Control 30
Subpart D Air Quality and Physical Agents 6
Subpart E Explosives 56
Subpart F Drilling and Rotary Jet Piercing 24
Subpart H Loading, Hauling, and Dumping 29
Subpart I Aerial Tramways 10
Subpart J Travelways 19
Subpart K Electricity 48
Subpart L Compressed Air and Boilers 10
Subpart M Machinery and Equipment 41
Subpart N Personal Protection 9
Subpart O Materials Storage and Handling 15
Subpart P Illumination 1
Subpart Q Safety Programs 8
Subpart R Personnel Hoisting 88
Subpart S Miscellaneous 10
Subpart T Safety Program for Surface Mobile Equipment 5
Part 57 · Underground M/NM Safety and Health Standards—Underground Metal and Nonmetal Mines 21 subparts

Part 57 on eCFR

Subpart A General 3
Subpart B Ground Control 11
Subpart C Fire Prevention and Control 56
Subpart D Air Quality, Radiation, Physical Agents, and Diesel Particulate Matter 25
Subpart E Explosives 59
Subpart F Drilling and Rotary Jet Piercing 27
Subpart G Ventilation 11
Subpart H Loading, Hauling, and Dumping 35
Subpart I Aerial Tramways 10
Subpart J Travelways and Escapeways 33
Subpart K Electricity 56
Subpart L Compressed Air and Boilers 10
Subpart M Machinery and Equipment 44
Subpart N Personal Protection 11
Subpart O Materials Storage and Handling 16
Subpart P Illumination 2
Subpart Q Safety Programs 10
Subpart R Personnel Hoisting 89
Subpart S Miscellaneous 14
Subpart T Safety Standards for Methane in Metal and Nonmetal Mines 77
Subpart U Safety Program for Surface Mobile Equipment 5
Part 58 · Health standards Health Standards for Metal and Nonmetal Mines 2 subparts

Part 58 on eCFR

Subpart A General 1
Subpart E Miscellaneous 2
Part 62 · Noise Occupational Noise Exposure
Part 100 · Civil penalties Criteria and Procedures for Proposed Assessment of Civil Penalties

Put it in your pocket

Install Pocket 30 CFR on your phone or tablet and save the regulations to the device — then search them underground, in the pit, or anywhere with no signal.

Open app view

Convenience copy of public-domain federal regulations, synced from the official eCFR. Not legal authority — verify anything that matters against eCFR.gov and current MSHA guidance.