⛏ Pocket 30 CFR
The mining regulations, searchable from your pocket. Type a citation (56.14107) or plain words ("guarding conveyor", "fall protection").
📱 Put it in your pocket
Install Pocket 30 CFR on your phone or tablet and save the regulations to the device — then search them underground, in the pit, or anywhere with no signal.
60 sections
§ 57.22005 Notice and appeal of placement or change in placement.
…t is served on the mine operator and representative of miners, unless a request for a hearing has been filed. Service of the Administrator's determination is complete upon mailing by registered or certified mail, return receipt requested. (b) The mine operato…
(a) The Administrator's determination of category or subcategory placement or change in placement shall become final upon the 30th day after it is served on the mine operator and representative of miners, unless a request for a hearing has been filed. Service of the Administrator's determination is complete upon mailing by registered or certified mail, return receipt requested.
(b) The mine operator or representative of miners may obtain review of the Administrator's determination by filing a request for a hearing with the Assistant Secretary of Labor for Mine Safety and Health, Mine Safety and Health Administration, 200 Constitution Avenue NW, Washington, DC 20210 within 30 days of the Administrator's determination. Service of a request for hearing is completed upon mailing by registered or certified mail, return receipt requested. Requests for a hearing shall be in writing and contain the following information:
(1) Name, address, and mine identification number;
(2) A concise statement of the reason why the Administrator's determination is inappropriate; and
(3) A copy of the Administrator's determination.
(c) The mine operator shall post a copy of the Administrator's determination and the request for a hearing on the mine bulletin board, and shall maintain the posting until the placement becomes final.
(d) Promptly after receipt of the request for a hearing, the Assistant Secretary shall refer to the Chief Administrative Law Judge, United States Department of Labor, the following:
(1) The request for a hearing;
(2) The Administrator's determination; and
(3) All information upon which the Administrator's determination was based.
(e) The hearing shall be regulated and conducted by an Administrative Law Judge in accordance with 29 CFR part 18, entitled, “Rules of Practice and Procedure for Administrative Hearings Before the Office of Administrative Law Judges.” Once the Administrative Law Judge has made an initial decision and served each party, the decision shall be final on the 30th day after service, unless discretionary review is undertaken by the Assistant Secretary or an appeal is filed by the mine operator or representative of the miners under paragraph (f) of this section.
(f) Within 30 days after service of an initial decision of an Administrative Law Judge, the Assistant Secretary for Mine Safety and Health may undertake a discretionary review of the initial decision, or the mine operator, or representative of the miners may appeal the initial decision of the Administrative Law Judge to the Assistant Secretary.
(1) The Assistant Secretary shall give notice of discretionary review to the mine operator and representative of the miners. The mine operator or representative of the miners shall give notice of an appeal to the other party. The notice shall specify the suggested changes and refer to the specific findings of fact, conclusions of law, and terms of the initial decision to be reviewed or appealed. The Assistant Secretary shall fix a time for filing any objections to the suggested changes and supporting reasons.
(2) The Assistant Secretary shall promptly notify the Administrative Law Judge of a discretionary review or an appeal. The entire record of the proceedings shall be transmitted to the Assistant Secretary for review.
(3) The Assistant Secretary shall make the final decision based upon consideration of the record of the proceedings. The final decision may affirm, modify, or set aside in whole or in part, the findings and conclusions contained in the initial decision. A statement of reasons for the action taken shall be included in the final decision. The final decision shall be served upon the mine operator and representative of the miners.
(g) Unless a decision by the Administrator for Metal and Nonmetal Mine Safety and Health, or the initial decision of the Administrative Law Judge, is appealed within 30 days, it becomes final, and is not subject to judicial review for the purposes of 5 U.S.C. 704. Only a decision by the Assistant Secretary shall be considered final Agency action for purposes of judicial review. Any such appeal must be filed in the appropriate circuit of the United States Court of Appeal.
(h) While a final decision of category placement is pending the following procedures shall apply:
(1) Where a mine has been classified as gassy prior to the effective date of these standards, existing gassy mines standards 30 CFR 57.21001 through 57.21101 (1986 Edition) shall continue to be applicable until placement is final.
(2) Where a mine has not been classified as gassy prior to the effective date of these standards and it is placed in Categories I through V, the mine shall comply with Category VI standards (§§ 57.22231, 57.22232, 57.22236, and 57.22238) until placement is final.
(3) Where a mine has been classified in Categories I through V after the effective date of these standards and category reassignment is being considered, the mine shall comply with the standards applicable to the category to which presently assigned until category placement is final.
§ 57.2 Definitions.
…ate or community in which the mine is located or by the Environmental Protection Agency in 40 CFR part 141, pages 169-182 revised as of July 1, 1977. Where no such requirements are applicable, the drinking water provided shall conform with the Public Health Se…
The following definitions apply to this part. In addition definitions contained in any subpart of part 57 apply in that subpart. If inconsistent with the general definitions in this section, the definition in the subpart will apply in that subpart:
Abandoned areas means areas in which work has been completed, no further work is planned, and travel is not permitted.
Abandoned mine means all work has stopped on the mine premises and an office with a responsible person in charge is no longer maintained at the mine.
Abandoned workings means deserted mine areas in which further work is not intended.
Active workings means areas at, in, or around a mine or plant where men work or travel.
American Table of Distances means the current edition of “The American Table of Distances for Storage of Explosives” published by the Institute of Makers of Explosives.
Approved means tested and accepted for a specific purpose by a nationally recognized agency.
Attended means presence of an individual or continuous monitoring to prevent unauthorized entry or access. In addition, areas containing explosive material at underground areas of a mine can be considered attended when all access to the underground areas of the mine is secured from unauthorized entry. Vertical shafts shall be considered secure. Inclined shafts or adits shall be considered secure when locked at the surface.
Authorized person means a person approved or assigned by mine management to perform a specific type of duty or duties or to be at a specific location or locations in the mine.
Auxilary fan means a fan used to deliver air to a working place off the main airstream; generally used with ventilation tubing.
Barricaded means obstructed to prevent the passage of persons, vehicles, or flying materials.
Barrier means a material object, or objects that separates, keeps apart, or demarcates in a conspicuous manner such as cones, a warning sign, or tape.
Berm means a pile or mound of material along an elevated roadway capable of moderating or limiting the force of a vehicle in order to impede the vehicle's passage over the bank of the roadway.
Blast area means the area in which concussion (shock wave), flying material, or gases from an explosion may cause injury to persons. In determining the blast area, the following factors, shall be considered:
(1) Geology or material to be blasted.
(2) Blast pattern.
(3) Burden, depth, diameter, and angle of the holes.
(4) Blasting experience of the mine.
(5) Delay system, powder factor, and pounds per delay.
(6) Type and amount of explosive material.
(7) Type and amount of stemming.
Blast site means the area where explosive material is handled during loading, including the perimeter formed by the loaded blastholes and 50 feet (15.2 meters) in all directions from loaded holes. A minimum distance of 30 feet (9.1 meters) may replace the 50-foot (15.2-meter) requirement if the perimeter of loaded holes is demarcated with a barrier. The 50-foot (15.2-meter) and alternative 30-foot (9.1-meter) requirements also apply in all directions along the full depth of the hole. In underground mines, at least 15 feet (4.6 meters) of solid rib, pillar, or broken rock can be substituted for the 50-foot (15.2-meter) distance. In underground mines utilizing a block-caving system or similar system, at least 6 feet (1.8 meters) of solid rib or pillar, including concrete reinforcement of at least 10 inches (254 millimeters), with overall dimensions of not less than 6 feet (1.8 meters) may be substituted for the 50-foot (15.2-meter) distance requirement.
Blasting agent means any substance classified as a blasting agent by the Department of Transportation in 49 CFR 173.114(a) (44 FR 31182, May 31, 1979) which is incorporated by reference. This document is available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration, and may be obtained from the U.S. Government Printing Office, Washington, DC 20402.
Blasting area means the area near blasting operations in which concussion or flying material can reasonably be expected to cause injury.
Blasting cap means a detonator which is initiated by a safety fuse.
Blasting circuit means the electrical circuit used to fire one or more electric blasting caps.
Blasting switch means a switch used to connect a power source to a blasting circuit.
Blowout means a sudden, violent, release of gas or liquid due to the reservoir pressure in a petroleum mine.
Booster means any unit of explosive or blasting agent used for the purpose of perpetuating or intensifying an initial detonation.
Booster fan means a fan installed in the main airstream or a split of the main airstream to increase airflow through a section or sections of a mine.
Capped fuse means a length of safety fuse to which a blasting cap has been attached.
Capped primer means a package or cartridge of explosives which is specifically designed to transmit detonation to other explosives and which contains a detonator.
Circuit breaker means a device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent setting without injury to itself when properly applied within its rating.
Combustible means capable of being ignited and consumed by fire.
Combustible material means a material that, in the form in which it is used and under the conditions anticipated, will ignite, burn, support combustion or release flammable vapors when subjected to fire or heat. Wood, paper, rubber, and plastics are examples of combustible materials.
Company official means a member of the company supervisory or technical staff.
Competent person means a person having abilities and experience that fully qualify him to perform the duty to which he is assigned.
Conductor means a material, usually in the form of a wire, cable, or bus bar, capable of carrying an electric current.
Delay connector means a nonelectric short interval delay device for use in delaying blasts which are initiated by detonating cord.
Detonating cord means a flexible cord containing a solid core of high explosives.
Detonator means any device containing a detonating charge that is used to initiate an explosive and includes but is not limited to blasting caps, electric blasting caps and non-electric instantaneous or delay blasting caps.
Distribution box means a portable apparatus with an enclosure through which an electric circuit is carried to one or more cables from a single incoming feed line; each cable circuit being connected through individual overcurrent protective devices.
Electric blasting cap means a detonator designed for and capable of being initiated by means of an electric current.
Electrical grounding means to connect with the ground to make the earth part of the circuit.
Employee means a person who works for wages or salary in the service of an employer.
Employer means a person or organization which hires one or more persons to work for wages or salary.
Emulsion means an explosive material containing substantial amounts of oxidizers dissolved in water droplets, surrounded by an immiscible fuel.
Escapeway means a passageway by which persons may leave a mine.
Explosive means any substance classified as an explosive by the Department of Transportation in 49 CFR 173.53, 173.88 and 173.100 which are incorporated by reference. Title 49 CFR is available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration, and may be obtained from the U.S. Government Printing Office, Washington, DC 20402.
Face or bank means that part of any mine where excavating is progressing or was last done.
Fire resistance rating means the time, in minutes or hours, that an assembly of materials will retain its protective characteristics or structural integrity upon exposure to fire.
Flame spread rating means the numerical designation that indicates the extent flame will spread over the surface of a material during a specified period of time.
Flammable means capable of being easily ignited and of burning rapidly.
Flammable gas means a gas that will burn in the normal concentrations of oxygen in the air.
Flammable liquid a liquid that has a flash point below 100 °F (37.8 °C), a vapor pressure not exceeding 40 pounds per square inch (absolute) at 100 °F (37.8 °C), and is known as a Class I liquid.
Flash point means the minimum temperature at which sufficient vapor is released by a liquid or solid to form a flammable vapor-air mixture at atmospheric pressure.
Geological area means an area characterized by the presence of the same ore bodies, the same stratigraphic sequence of beds, or the same ore-bearing geological formation.
Highway means any public street, public alley or public road.
High potential means more than 650 volts.
Hoist means a power driven windlass or drum used for raising ore, rock, or other material from a mine, and for lowering or raising persons and material.
Igniter cord means a fuse, cordlike in appearance, which burns progressively along its length with an external flame at the zone of burning, and is used for lighting a series of safety fuses in the desired sequence.
Insulated means separated from other conducting surfaces by a dielectric substance permanently offering a high resistance to the passage of current and to disruptive discharge through the substance. When any substance is said to be insulated, it is understood to be insulated in a manner suitable for the conditions to which it is subjected. Otherwise, it is, within the purpose of this definition, uninsulated. Insulating covering is one means for making the conductor insulated.
Insulation means a dielectric substance offering a high resistance to the passage of current and to a disruptive discharge through the substance.
Laminated partition means a partition composed of the following material and minimum nominal dimensions: 1/2-inch-thick plywood, 1/2-inch-thick gypsum wallboard, 1/8-inch-thick low carbon steel, and 1/4-inch-thick plywood, bonded together in that order (IME-22 Box). A laminated partition also includes alternative construction materials described in the Institute of Makers of Explosives (IME) Safety Library Publication No. 22, “Recommendations for the Safe Transportation of Detonators in a Vehicle with Other Explosive Materials” (May 1993), and the “Generic Loading Guide for the IME-22 Container” (October 1993). The IME is located at 1120 19th Street NW., Suite 310, Washington, DC 20036-3605; 202-429-9280; https://www.ime.org. This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies are available at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at all Metal and Nonmetal Mine Safety and Health District Offices, or available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
Lay means the distance parallel to the axis of the rope in which a strand makes one complete turn about the axis of the rope.
Loading means placing explosive material either in a blasthole or against the material to be blasted.
Low potential means 650 volts or less.
Magazine means a facility for the storage of explosives, blasting agents, or detonators.
Main fan means a fan that controls the entire airflow of the mine, or the airflow of one of the major air circuits.
Major electrical installation means an assemblage of stationary electrical equipment for the generation, transmission, distribution, or conversion of electrical power.
Mantrip means a trip on which persons are transported to and from a work area.
Mill includes any ore mill, sampling works, concentrator, and any crushing, grinding, or screening plant used at, and in connection with, an excavation or mine.
Mine atmosphere means any point at least 12 inches away from the back, face, rib, and floor in any mine; and additionally, in a Category IV mine, at least 3 feet laterally away from the collar of a borehole which releases gas into a mine.
Mine opening means any opening or entrance from the surface into a mine.
Misfire means the complete or partial failure of a blasting charge to explode as planned.
Mobile equipment means wheeled, skid-mounted, track-mounted, or rail-mounted equipment capable of moving or being moved.
Multipurpose dry-chemical fire extinguisher means an extinguisher having a rating of at least 2-A:10-B:C and containing a nominal 4.5 pounds or more of dry-chemical agent.
Noncombustible material means a material that, in the form in which it is used and under the conditions anticipated, will not ignite, burn, support combustion, or release flammable vapors when subjected to fire or heat. Concrete, masonry block, brick, and steel are examples of noncombustible materials.
Non-electric delay blasting cap means a detonator with an integral delay element and capable of being initiated by miniaturized detonating cord.
Outburst means the sudden, violent release of solids and high-pressure occluded gases, including methane in a domal salt mine.
Overburden means material of any nature, consolidated or unconsolidated, that overlies a deposit of useful materials or ores that are to be mined.
Overload means that current which will cause an excessive or dangerous temperature in the conductor or conductor insulation.
Permissible means a machine, material, apparatus, or device which has been investigated, tested, and approved by the Bureau of Mines or the Mine Safety and Health Administration, and is maintained in permissible condition.
Potable water means water which shall meet the applicable minimum health requirements for drinking water established by the State or community in which the mine is located or by the Environmental Protection Agency in 40 CFR part 141, pages 169-182 revised as of July 1, 1977. Where no such requirements are applicable, the drinking water provided shall conform with the Public Health Service Drinking Water Standards, 42 CFR part 72, subpart J, pages 527-533, revised as of October 1, 1976. Publications to which references are made in this definition are hereby made a part hereof. These incorporated publications are available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration.
Powder chest means a substantial, nonconductive portable container equipped with a lid and used at blasting sites for explosives other than blasting agents.
Primer means a unit, package, or cartridge of explosives used to initiate other explosives or blasting agents, and which contains a detonator.
Reverse-current protection means a method or device used on direct-current circuits or equipment to prevent the flow of current in a reverse direction.
Rock burst means a sudden and violent failure of overstressed rock resulting in the instantaneous release of large amounts of accumulated energy. Rock burst does not include a burst resulting from pressurized mine gases.
Rock fixture means any tensioned or nontensioned device or material inserted into the ground to strengthen or support the ground.
Roll protection means a framework, safety canopy or similar protection for the operator when equipment overturns.
Safety can means an approved container, of not over 5 gallons capacity, having a spring-closing lid and spout cover.
Safety fuse means a flexible cord containing an internal burning medium by which fire is conveyed at a continuous and uniform rate for the purpose of firing blasting caps or a black powder charge.
Safety switch means a sectionalizing switch that also provides shunt protection in blasting circuits between the blasting switch and the shot area.
Scaling means removal of insecure material from a face or highwall.
Secondary safety connection means a second connection between a conveyance and rope, intended to prevent the conveyance from running away or falling in the event the primary connection fails.
Shaft means a vertical or inclined shaft, a slope, incline, or winze.
Short circuit means an abnormal connection of relatively low resistance, whether made accidentally or intentionally, between two points of difference potential in a circuit.
Slurry (as applied to blasting). See “Water gel.”
Storage facility means the entire class of structures used to store explosive materials. A “storage facility” used to store blasting agents corresponds to a BATF Type 4 or 5 storage facility.
Storage tank means a container exceeding 60 gallons in capacity used for the storage of flammable or combustible liquids.
Stray current means that portion of a total electric current that flows through paths other than the intended circuit.
Substantial construction means construction of such strength, material, and workmanship that the object will withstand all reasonable shock, wear, and usage to which it will be subjected.
Suitable means that which fits, and has the qualities or qualifications to meet a given purpose, occasion, condition, function, or circumstance.
Travelway means a passage, walk or way regularly used and designated for persons to go from one place to another.
Water gel or Slurry (as applied to blasting) means an explosive or blasting agent containing substantial portions of water.
Wet drilling means the continuous application of water through the central hole of hollow drill steel to the bottom of the drill hole.
Working level (WL) means any combination of the short-lived radon daughters in one liter of air that will result in ultimate emission of 1.3 × 10 5 MeV (million electron volts) of potential alpha energy, and exposure to these radon daughters over a period of time is expressed in terms of “working level months” (WLM). Inhalation of air containing a radon daughter concentration of 1 WL for 173 hours results in an exposure of 1 WLM.”
Working place means any place in or about a mine where work is being performed.
§ 57.5046 Protection against radon gas.
Where radon daughter concentrations exceed 10 WL, respirator protection against radon gas shall be provided in addition to protection against radon daughters. Protection against radon gas shall be provided by supplied air devices or by face masks containing ab…
Where radon daughter concentrations exceed 10 WL, respirator protection against radon gas shall be provided in addition to protection against radon daughters. Protection against radon gas shall be provided by supplied air devices or by face masks containing absorbent material capable of removing both the radon and its daughters.
§ 57.12003 Trailing cable overload protection.
Individual overload protection or short circuit protection shall be provided for the trailing cables of mobile equipment.…
Individual overload protection or short circuit protection shall be provided for the trailing cables of mobile equipment.
§ 57.4760 Shaft mines.
…as an escapeway under § 57.11053 or at other locations that provide equivalent protection; (ii) Constructed and maintained according to Table C-3; (iii) Provided with a means of remote closure at landings of timbered intake shafts unless a person specificall…
(a) Shaft mines shall be provided with at least one of the following means to control the spread of fire, smoke, and toxic gases underground in the event of a fire: control doors, reversal of mechanical ventilation, or effective evacuation procedures. Under this standard, “shaft mine” means a mine in which any designated escapeway includes a mechanical hoisting device or a ladder ascent.
(1) Control doors. If used as an alternative, control doors shall be—
(i) Installed at or near shaft stations of intake shafts and any shaft designated as an escapeway under § 57.11053 or at other locations that provide equivalent protection;
(ii) Constructed and maintained according to Table C-3;
(iii) Provided with a means of remote closure at landings of timbered intake shafts unless a person specifically designated to close each door in the event of a fire can reach the door within three minutes;
(iv) Closed or opened only according to predetermined conditions and procedures;
(v) Constructed so that once closed they will not reopen as a result of a differential in air pressure;
(vi) Constructed so that they can be opened from either side by one person, or be provided with a personnel door that can be opened from either side; and
(vii) Clear of obstructions.
(2) Mechanical ventilation reversal. If used as an alternative, reversal of mechanical ventilation shall—
(i) Provide at all times at least the same degree of protection to persons underground as would be afforded by the installation of control doors;
(ii) Be accomplished by a main fan. If the main fan is located underground—
(A) The cable or conductors supplying power to the fan shall be routed through areas free of fire hazards; or
(B) The main fan shall be equipped with a second, independent power cable or set of conductors from the surface. The power cable or conductors shall be located so that an underground fire disrupting power in one cable or set of conductors will not affect the other; or
(C) A second fan capable of accomplishing ventilation reversal shall be available for use in the event of failure of the main fan;
(iii) Provide rapid air reversal that allows persons underground time to exit in fresh air by the second escapeway or find a place of refuge; and
(iv) Be done according to predetermined conditions and procedures.
(3) Evacuation. If used as an alternative, effective evacuation shall be demonstrated by actual evacuation of all persons underground to the surface in ten minutes or less through routes that will not expose persons to heat, smoke, or toxic fumes in the event of a fire.
(b) If the destruction of any bulkhead on an inactive level would allow fire contaminants to reach an escapeway, that bulkhead shall be constructed and maintained to provide at least the same protection as required for control doors under Table C-3.
Table C-3—Control Door Construction
§ 57.5005T Control of exposure to airborne contaminants.
…ive equipment in accordance with training and instruction. (b) A written respiratory protection program consistent with the requirements of ASTM F3387-19, Standard Practice for Respiratory Protection, approved August 1, 2019, which is incorporated by referenc…
As of April 8, 2026, the following is required. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention of contamination, removal by exhaust ventilation, or by dilution with uncontaminated air. However, where accepted engineering control measures have not been developed or when necessary by the nature of work involved (for example, while establishing controls or occasional entry into hazardous atmospheres to perform maintenance or investigation), employees may work for reasonable periods of time in concentrations of airborne contaminants exceeding permissible levels if they are protected by appropriate respiratory protective equipment. Whenever respiratory protective equipment is used, its selection, fitting, maintenance, cleaning, training, supervision, and use shall meet the following minimum requirements:
(a) Respirators approved by NIOSH under 42 CFR part 84 which are applicable and suitable for the purpose intended shall be furnished and miners shall use the protective equipment in accordance with training and instruction.
(b) A written respiratory protection program consistent with the requirements of ASTM F3387-19, Standard Practice for Respiratory Protection, approved August 1, 2019, which is incorporated by reference into this section with the approval of the Director of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. This incorporation by reference (IBR) material is available for inspection at the Mine Safety and Health Administration (MSHA) and at the National Archives and Records Administration (NARA). Contact MSHA at: MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; (202) 693-9440; or any Mine Safety and Health Enforcement District Office. For information on the availability of this material at NARA, visit www.archives.gov/federal-register/cfr/ibr-locations or email fr.inspection@nara.gov. The material may be obtained from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; www.astm.org.
(c) When respiratory protection is used in atmospheres immediately dangerous to life or health (IDLH), the presence of at least one other person with backup equipment and rescue capability shall be required in the event of failure of the respiratory equipment.
§ 57.19010 Location of hoist controls.
…used so that the noise from machinery or other sources will not prevent hoistmen from hearing signals.…
Hoist controls shall be placed or housed so that the noise from machinery or other sources will not prevent hoistmen from hearing signals.
§ 57.19055 Availability of hoist operator for manual hoists.
When a manually operated hoist is used, a qualified hoistman shall remain within hearing of the telephone or signal device at all times while any person is underground.…
When a manually operated hoist is used, a qualified hoistman shall remain within hearing of the telephone or signal device at all times while any person is underground.
§ 57.4263 Underground belt conveyors.
Fire protection shall be provided at the head, tail, drive, and take-up pulleys of underground belt conveyors. Provisions shall be made for extinguishing fires along the beltline. Fire protection shall be of a type, size, and quantity that can extinguish fires…
Fire protection shall be provided at the head, tail, drive, and take-up pulleys of underground belt conveyors. Provisions shall be made for extinguishing fires along the beltline. Fire protection shall be of a type, size, and quantity that can extinguish fires of any class in their early stages which could occur as a result of the fire hazards present.
§ 57.10007 Falling object protection.
Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.…
Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.
§ 57.11025 Railed landings, backguards, and other protection for fixed ladders.
…ve substantial railed landings at least every 30 feet unless backguards or equivalent protection such as safety belts and safety lines, are provided.…
Fixed ladders, except on mobile equipment, shall be offset and have substantial railed landings at least every 30 feet unless backguards or equivalent protection such as safety belts and safety lines, are provided.
§ 57.11026 Protection for inclined fixed ladders.
…e horizontal and 30 feet or more in length shall have backguards, cages or equivalent protection, starting at a point not more than seven feet from the bottom of the ladders.…
Fixed ladders 70 degrees to 90 degrees from the horizontal and 30 feet or more in length shall have backguards, cages or equivalent protection, starting at a point not more than seven feet from the bottom of the ladders.
§ 57.19110 Overhead protection for shaft deepening work.
A substantial bulkhead or equivalent protection shall be provided above persons at work deepening a shaft.…
A substantial bulkhead or equivalent protection shall be provided above persons at work deepening a shaft.
§ 57.4761 Underground shops.
… timber or other combustible material, the control doors or bulkheads shall provide protection at least equivalent to a door constructed of no less than one-quarter inch of plate steel with channel or angle-iron reinforcement to minimize warpage. The framework…
To confine or prevent the spread of toxic gases from a fire originating in an underground shop where maintenance work is routinely done on mobile equipment, one of the following measures shall be taken: use of control doors or bulkheads, routing of the mine shop air directly to an exhaust system, reversal of mechanical ventilation, or use of an automatic fire suppression system in conjunction with an alternate escape route. The alternative used shall at all times provide at least the same degree of safety as control doors or bulkheads.
(a) Control doors or bulkheads. If used as an alternative, control doors or bulkheads shall meet the following requirements:
(1) Each control door or bulkhead shall be constructed to serve as a barrier to fire, the effects of fire, and air leakage at each opening to the shop.
(2) Each control door shall be—
(i) Constructed so that, once closed, it will not reopen as a result of a differential in air pressure;
(ii) Constructed so that it can be opened from either side by one person or be provided with a personnel door that can be opened from either side;
(iii) Clear of obstructions; and
(iv) Provided with a means of remote or automatic closure unless a person specifically designated to close the door in the event of a fire can reach the door within three minutes.
(3) If located 20 feet or more from exposed timber or other combustible material, the control doors or bulkheads shall provide protection at least equivalent to a door constructed of no less than one-quarter inch of plate steel with channel or angle-iron reinforcement to minimize warpage. The framework assembly of the door and the surrounding bulkhead, if any, shall be at least equivalent to the door in fire and air-leakage resistance, and in physical strength.
(4) If located less than 20 feet from exposed timber or other combustibles, the control door or bulkhead shall provide protection at least equivalent to a door constructed of two layers of wood, each a minimum of three-quarters of an inch in thickness. The wood-grain of one layer shall be perpendicular to the wood-grain of the other layer. The wood construction shall be covered on all sides and edges with no less than 24-gauge sheet steel. The framework assembly of the door and the surrounding bulkhead, if any, shall be at least equivalent to the door in fire and air-leakage resistance, and in physical strength. Roll-down steel doors with a fire-resistance rating of 1 1/2 hours or greater, but without an insulation core, are acceptable provided that an automatic sprinkler or deluge system is installed that provides even coverage of the door on both sides.
(b) Routing air to exhaust system. If used as an alternative, routing the mine shop exhaust air directly to an exhaust system shall be done so that no person would be exposed to toxic gases in the event of a shop fire.
(c) Mechanical ventilation reversal. If used as an alternative, reversal of mechanical ventilation shall—
(1) Be accomplished by a main fan. If the main fan is located underground:
(i) The cable or conductors supplying power to the fan shall be routed through areas free of fire hazards; or
(ii) The main fan shall be equipped with a second, independent power cable or set of conductors from the surface. The power cable or conductors shall be located so that an underground fire disrupting power in one cable or set of conductors will not affect the other; or
(iii) A second fan capable of accomplishing ventilation reversal shall be available for use in the event of failure of the main fan;
(2) Provide rapid air reversal that allows persons underground time to exit in fresh air by the second escapeway or find a place of refuge; and
(3) Be done according to predetermined conditions and procedures.
(d) Automatic fire suppression system and escape route. If used as an alternative, the automatic fire suppression system and alternate escape route shall meet the following requirements:
(1) The suppression system shall be—
(i) Located in the shop area;
(ii) The appropriate size and type for the particular fire hazards involved; and
(iii) Inspected at weekly intervals and properly maintained.
(2) The escape route shall bypass the shop area so that the route will not be affected by a fire in the shop area.
§ 57.5005 Control of exposure to airborne contaminants.
…dards Institute and entitled “American National Standards Practices for Respiratory Protection ANSI Z88.2-1969,” approved August 11, 1969, which is hereby incorporated by reference and made a part hereof. This publication may be obtained from the American Nati…
The following is required until April 7, 2026. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention of contamination, removal by exhaust ventilation, or by dilution with uncontaminated air. However, where accepted engineering control measures have not been developed or when necessary by the nature of work involved (for example, while establishing controls or occasional entry into hazardous atmospheres to perform maintenance or investigation), employees may work for reasonable periods of time in concentrations of airborne contaminants exceeding permissible levels if they are protected by appropriate respiratory protective equipment. Whenever respiratory protective equipment is used a program for selection, maintenance, training, fitting, supervision, cleaning, and use shall meet the following minimum requirements:
(a) Respirators approved by NIOSH under 42 CFR part 84 which are applicable and suitable for the purpose intended shall be furnished and miners shall use the protective equipment in accordance with training and instruction.
(b) A respirator program consistent with the requirements of ANSI Z88.2-1969, published by the American National Standards Institute and entitled “American National Standards Practices for Respiratory Protection ANSI Z88.2-1969,” approved August 11, 1969, which is hereby incorporated by reference and made a part hereof. This publication may be obtained from the American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036; http://www.ansi.org, or may be examined in any Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration.
(c) When respiratory protection is used in atmospheres immediately harmful to life, the presence of at least one other person with backup equipment and rescue capability shall be required in the event of failure of the respiratory equipment.
§ 57.5060 Limit on exposure to diesel particulate matter.
…exposure to as low a level as feasible and must be supplemented with respiratory protection in accordance with § 57.5005(a), (b), and paragraphs (d)(1) through (d)(8) of this section. (1) Air purifying respirators must be equipped with the following: (i) Fil…
(a) A miner's personal exposure to diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift airborne concentration of 308 micrograms of elemental carbon per cubic meter of air (308EC µg/m 3). [This interim permissible exposure limit (PEL) remains in effect until the final DPM exposure limit becomes effective. When the final DPM exposure limit becomes effective, MSHA will publish a document in the Federal Register.]
(b)(1) Effective May 20, 2006, a miner's personal exposure to diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift airborne concentration of 308 micrograms of elemental carbon per cubic meter of air (308EC µg/m 3).
(2) Effective January 20, 2007, a miner's personal exposure to diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350 micrograms of total carbon per cubic meter of air (350TC µg/m 3).
(3) Effective May 20, 2008, a miner's personal exposure to diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift airborne concentration of 160 micrograms of total carbon per cubic meter of air (160TC µg/m 3).
(c)(1) If a mine requires additional time to come into compliance with the final DPM limit established in § 57.5060 (b) due to technological or economic constraints, the operator of the mine may file an application with the District Manager for a special extension.
(2) The mine operator must certify on the application that the operator has posted one copy of the application at the mine site for at least 30 days prior to the date of application, and has provided another copy to the authorized representative of miners.
(3) No approval of a special extension shall exceed a period of one year from the date of approval. Mine operators may file for additional special extensions provided each extension does not exceed a period of one year. An application must include the following information:
(i) Documentation supporting that controls are technologically or economically infeasible at this time to reduce the miner's exposure to the final DPM limit.
(ii) The most recent DPM monitoring results.
(iii) The actions the operator will take during the extension to minimize exposure of miners to DPM.
(4) A mine operator must comply with the terms of any approved application for a special extension, post a copy of the approved application for a special extension at the mine site for the duration of the special extension period, and provide a copy of the approved application to the authorized representative of miners.
(d) The mine operator must install, use, and maintain feasible engineering and administrative controls to reduce a miner's exposure to or below the applicable DPM PEL established in this section. When controls do not reduce a miner's DPM exposure to the PEL, controls are infeasible, or controls do not produce significant reductions in DPM exposures, controls must be used to reduce the miner's exposure to as low a level as feasible and must be supplemented with respiratory protection in accordance with § 57.5005(a), (b), and paragraphs (d)(1) through (d)(8) of this section.
(1) Air purifying respirators must be equipped with the following:
(i) Filters certified by NIOSH under 30 CFR part 11 (appearing in the July 1, 1994 edition of 30 CFR, parts 1 to 199) as a high efficiency particulate air (HEPA) filter;
(ii) Filters certified by NIOSH under 42 CFR part 84 as 99.97% efficient; or
(iii) Filters certified by NIOSH for DPM.
(2) Non-powered, negative-pressure, air purifying, particulate-filter respirators shall use an R- or P-series filter or any filter certified by NIOSH for DPM. An R-series filter shall not be used for longer than one work shift.
(3) The mine operator must provide a confidential medical evaluation by a physician or other licensed health care professional (PLHCP), at no cost to the miner, to determine the miner's ability to use a respirator before the miner is required to be fit tested or to use a respirator at the mine. If the PLHCP determines that the miner cannot wear a negative pressure respirator, the mine operator must make certain that the PLHCP evaluates the miner's ability to wear a powered air purifying respirator (PAPR).
(4) The mine operator must provide the miner with an opportunity to discuss their evaluation results with the PLHCP before the PLHCP submits the written determination to the mine operator regarding the miner's ability to wear a respirator. If the miner disagrees with the evaluation results of the PLHCP, the miner may submit within 30 days additional evidence of his or her medical condition to the PLHCP.
(5) The mine operator must obtain a written determination from the PLHCP regarding the miner's ability to wear a respirator, and the mine operator must assure that the PLHCP provides a copy of the determination to the miner.
(6) The miner must be reevaluated when the mine operator has reason to believe that conditions have changed which could adversely affect the miner's ability to wear the respirator.
(7) Upon written notification that the PLHCP has determined that the miner is unable to wear a respirator, including a PAPR, the miner must be transferred to work in an existing position in an area of the same mine where respiratory protection is not required. The miner must be transferred within 30 days of the final determination by the PLHCP.
(i) The miner must continue to receive compensation at no less than the regular rate of pay in the classification held by that miner immediately prior to the transfer.
(ii) Increases in wages of the transferred miner must be based upon the new work classification.
(8) The mine operator must maintain a record of the identity of the PLHCP and the most recent written determination of each miner's ability to wear a respirator for the duration of the miner's employment plus six months.
(e) Rotation of miners shall not be considered an acceptable administrative control used for compliance with the DPM standard.
§ 57.1 Purpose and scope.
…the Federal Mine Safety and Health Act of 1977. The purpose of these standards is the protection of life, the promotion of health and safety, and the prevention of accidents.…
This part 57 sets forth mandatory safety and health standards for each underground metal or nonmetal mine, including related surface operations, subject to the Federal Mine Safety and Health Act of 1977. The purpose of these standards is the protection of life, the promotion of health and safety, and the prevention of accidents.
§ 57.3201 Location for performing scaling.
…om a location which will not expose persons to injury from falling material, or other protection from falling material shall be provided.…
Scaling shall be performed from a location which will not expose persons to injury from falling material, or other protection from falling material shall be provided.
§ 57.4160 Underground electric substations and liquid storage facilities.
…rete, one-half inch of gunite, or other noncombustible materials with equivalent fire protection characteristics.…
The requirements of this standard apply to underground areas only.
(a) Areas within 25 feet of the following shall be free of combustible materials:
(1) Electric substations.
(2) Unburied, combustible liquid storage tanks.
(3) Any group of containers used for storage of more than 60 gallons of combustible liquids.
(b) This standard does not apply to installed wiring or timber that is coated with at least one inch of shotcrete, one-half inch of gunite, or other noncombustible materials with equivalent fire protection characteristics.
§ 57.4261 Shaft-station waterlines.
…utlets that are located at underground shaft stations and are part of the mine's fire protection system shall have at least one fitting located for, and capable of, immediate connection to firefighting equipment.…
Waterline outlets that are located at underground shaft stations and are part of the mine's fire protection system shall have at least one fitting located for, and capable of, immediate connection to firefighting equipment.
§ 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms.
…le liquids, pump rooms, compressor rooms, and hoist rooms shall be provided with fire protection of a type, size, and quantity that can extinguish fires of any class in their early stages which could occur as a result of the hazards present.…
Transformer stations, storage and dispensing areas for combustible liquids, pump rooms, compressor rooms, and hoist rooms shall be provided with fire protection of a type, size, and quantity that can extinguish fires of any class in their early stages which could occur as a result of the hazards present.
§ 57.4560 Mine entrances.
…ges; or (b) Covered with shotcrete, gunite, or other material with equivalent fire protection characteristics; or (c) Coated with fire-retardant paint or other material to reduce its flame spread rating to 25 or less and maintained in that condition.…
For at least 200 feet inside the mine portal or collar timber used for ground support in intake openings and in exhaust openings that are designated as escapeways shall be—
(a) Provided with a fire suppression system, other than fire extinguishers and water hoses, capable of controlling a fire in its early stages; or
(b) Covered with shotcrete, gunite, or other material with equivalent fire protection characteristics; or
(c) Coated with fire-retardant paint or other material to reduce its flame spread rating to 25 or less and maintained in that condition.
§ 57.5042 Revised exposure levels.
…hters different from those prescribed in 57.5038 are recommended by the Environmental Protection Agency and approved by the President, no employee shall be permitted to receive exposures in excess of those levels after the effective dates established by the Ag…
If levels of permissible exposures to concentrations of radon daughters different from those prescribed in 57.5038 are recommended by the Environmental Protection Agency and approved by the President, no employee shall be permitted to receive exposures in excess of those levels after the effective dates established by the Agency.
§ 57.5065 Fueling practices.
…. (b) The operator must only use fuel additives registered by the U.S. Environmental Protection Agency in diesel powered equipment operated in underground areas.…
(a) Diesel fuel used to power equipment in underground areas must not have a sulfur content greater than 0.05 percent. The operator must retain purchase records that demonstrate compliance with this requirement for one year after the date of purchase.
(b) The operator must only use fuel additives registered by the U.S. Environmental Protection Agency in diesel powered equipment operated in underground areas.
§ 57.6304 Primer protection.
(a) Tamping shall not be done directly on a primer. (b) Rigid cartridges of explosives or blasting agents that are 4 inches (100 millimeters) in diameter or larger shall not be dropped on the primer except where the blasthole contains sufficient depth of wate…
(a) Tamping shall not be done directly on a primer.
(b) Rigid cartridges of explosives or blasting agents that are 4 inches (100 millimeters) in diameter or larger shall not be dropped on the primer except where the blasthole contains sufficient depth of water to protect the primer from impact. Slit packages of prill, water gel, or emulsions are not considered rigid cartridges and may be drop loaded.
§ 57.6403 Branch circuits.
…late the circuits to be used. (b) At least one safety switch or equivalent method of protection shall be located outside the blast area and shall be in the open position until persons are withdrawn.…
(a) If electric blasting includes the use of branch circuits, each branch shall be equipped with a safety switch or equivalent method to isolate the circuits to be used.
(b) At least one safety switch or equivalent method of protection shall be located outside the blast area and shall be in the open position until persons are withdrawn.
§ 57.4201 Inspection.
… are exempt from these inspection requirements if the systems are used solely for the protection of property and no persons would be affected by a fire. (b) At the completion of each inspection or test required by this standard, the person making the inspecti…
(a) Firefighting equipment shall be inspected according to the following schedules:
(1) Fire extinguishers shall be inspected visually at least once a month to determine that they are fully charged and operable.
(2) At least once every twelve months, maintenance checks shall be made of mechanical parts, the amount and condition of extinguishing agent and expellant, and the condition of the hose, nozzle, and vessel to determine that the fire extinguishers will operate effectively.
(3) Fire extinguishers shall be hydrostatically tested according to Table C-1 or a schedule based on the manufacturer's specifications to determine the integrity of extinguishing agent vessels.
(4) Water pipes, valves, outlets, hydrants, and hoses that are part of the mine's firefighting system shall be visually inspected at least once every three months for damage or deterioration and use-tested at least once every twelve months to determine that they remain functional.
(5) Fire suppression systems shall be inspected at least once every twelve months. An inspection schedule based on the manufacturer's specifications or the equivalent shall be established for individual components of a system and followed to determine that the system remains functional. Surface fire suppression systems are exempt from these inspection requirements if the systems are used solely for the protection of property and no persons would be affected by a fire.
(b) At the completion of each inspection or test required by this standard, the person making the inspection or test shall certify that the inspection or test has been made and the date on which it was made. Certifications of hydrostatic testing shall be retained until the fire extinguisher is retested or permanently removed from service. Other certifications shall be retained for one year.
Table C-1—Hydrostatic Test Intervals for Fire Extinguishers
§ 57.4462 Storage of combustible liquids underground.
…ete, one-half inch of gunite, or other noncombustible material with equivalent fire protection characteristics; and (4) Separated from explosives or blasting agents, shaft stations, and ignition sources including electric equipment that could create sufficien…
The requirements of this standard apply to underground areas only.
(a) Combustible liquids, including oil or grease, shall be stored in non-glass containers or storage tanks. The containers or storage tanks shall be—
(1) Capable of withstanding working pressures and stresses and compatible with the type of liquid stored;
(2) Maintained in a manner that prevents leakage;
(3) Located in areas free of combustible materials or in areas where any exposed combustible materials are coated with one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire protection characteristics; and
(4) Separated from explosives or blasting agents, shaft stations, and ignition sources including electric equipment that could create sufficient heat or sparks to pose a fire hazard. Separation shall be sufficient to prevent the occurrence or minimize the spread of fire.
(b) Storage tanks shall be vented or otherwise constructed to prevent development of pressure or vacuum as a result of filling, emptying, or atmospheric temperature changes. Vents for storage of Class II or IIIA liquids shall be isolated or separated from ignition sources.
(c) At permanent storage areas for combustible liquids, means shall be provided for confinement or removal of the contents of the largest storage tank in the event of tank rupture.
(d) All piping, valves, and fittings shall be:
(1) Capable of withstanding working pressures and stresses;
(2) Compatible with the type of liquid stored; and
(3) Maintained in a manner which prevents leakage.
§ 57.4505 Fuel lines to underground areas.
…ete, one-half inch of gunite, or other noncombustible material with equivalent fire protection characteristics. (c) Provisions shall be made for control or containment of the entire volume of the fuel line so that leakage will not create a fire hazard.…
Fuel lines into underground storage or dispensing areas shall be drained at the completion of each transfer of fuel unless the following requirements are met:
(a) The valve at the supply source shall be kept closed when fuel is not being transferred.
(b) The fuel line shall be—
(1) Capable of withstanding working pressures and stresses;
(2) Located to prevent damage; and
(3) Located in areas free of combustible materials or in areas where any exposed combustible materials are coated with one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire protection characteristics.
(c) Provisions shall be made for control or containment of the entire volume of the fuel line so that leakage will not create a fire hazard.
§ 57.5037 Radon daughter exposure monitoring.
… in section 14.3 of ANSI N13.8-1973, entitled “American National Standard Radiation Protection in Uranium Mines,” approved July 18, 1973, pages 13-15, by the American National Standards Institute, Inc., which is incorporated by reference and made a part of the…
(a) In all mines at least one sample shall be taken in exhaust mine air by a competent person to determine if concentrations of radon daughters are present. Sampling shall be done using suggested equipment and procedures described in section 14.3 of ANSI N13.8-1973, entitled “American National Standard Radiation Protection in Uranium Mines,” approved July 18, 1973, pages 13-15, by the American National Standards Institute, Inc., which is incorporated by reference and made a part of the standard or equivalent procedures and equipment acceptable to the Administrator, MSHA Metal and Nonmetal Mine Safety and Health district office. This publication may be examined at any Metal and Nonmetal Mine Safety and Health Subdistrict Office of the Mine Safety and Health Administration, or may be obtained from the American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036; http://www.ansi.org. The mine operator may request that the required exhaust mine air sampling be done by the Mine Safety and Health Administration. If concentrations of radon daughters in excess of 0.1 WL are found in an exhaust air sample, thereafter—
(1) Where uranium is mined—radon daughter concentrations representative of worker's breathing zone shall be determined at least every two weeks at random times in all active working areas such as stopes, drift headings, travelways, haulageways, shops, stations, lunch rooms, magazines, and any other place or location where persons work, travel, or congregate. However, if concentrations of radon daughters are found in excess of 0.3 WL in an active working area, radon daughter concentrations thereafter shall be determined weekly in that working area until such time as the weekly determinations in that area have been 0.3 WL or less for 5 consecutive weeks.
(2) Where uranium is not mined—when radon daughter concentrations between 0.1 and 0.3 WL are found in an active working area, radon daughter concentration measurements representative of worker's breathing zone shall be determined at least every 3 months at random times until such time as the radon daughter concentrations in that area are below 0.1 WL, and annually thereafter. If concentrations of radon daughters are found in excess of 0.3 WL in an active working area radon daughter concentrations thereafter shall be determined at least weekly in that working area until such time as the weekly determinations in that area have been 0.3 WL or less for 5 consecutive weeks.
(b) If concentrations of radon daughters less than 0.1 WL are found in an exhaust mine air sample, thereafter:
(1) Where uranium is mined—at least one sample shall be taken in the exhaust mine air monthly.
(2) Where uranium is not mined—no further exhaust mine air sampling is required.
(c) The sample date, locations, and results obtained under (a) and (b) above shall be recorded and retained at the mine site or nearest mine office for at least two years and shall be made available for inspection by the Secretary or his authorized representative.
§ 57.5047 Gamma radiation surveys.
…ce with American National Standards (ANSI) Standard N13.8-1973, entitled “Radiation Protection in Uranium Mines”, section 14.1 page 12, which is hereby incorporated by reference and made a part hereof. This publication may be examined in any Metal and Nonmetal…
(a) Gamma radiation surveys shall be conducted annually in all underground mines where radioactive ores are mined.
(b) Surveys shall be in accordance with American National Standards (ANSI) Standard N13.8-1973, entitled “Radiation Protection in Uranium Mines”, section 14.1 page 12, which is hereby incorporated by reference and made a part hereof. This publication may be examined in any Metal and Nonmetal Mine Safety and Health District Office, Mine Safety and Health Administration, or may be obtained from the American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036; http://www.ansi.org.
(c) Where average gamma radiation measurements are in excess of 2.0 milliroentgens per hour in the working place, gamma radiation dosimeters shall be provided for all persons affected, and records of cumulative individual gamma radiation exposure shall be kept.
(d) Annual individual gamma radiation exposure shall not exceed 5 rems.
§ 57.5067 Engines.
…r exceed the applicable particulate matter emission requirements of the Environmental Protection Administration listed in Table 57.5067-1, as follows: Table 57.5067-1 (b) For purposes of paragraph (a): (1) The term “introduced” means any engine added to the…
(a) Any diesel engine introduced into an underground area of a mine covered by this part after July 5, 2001, other than an engine in an ambulance or fire fighting equipment which is utilized in accordance with mine fire fighting and evacuation plans, must either:
(1) Have affixed a plate evidencing approval of the engine pursuant to subpart E of Part 7 of this title or pursuant to Part 36 of this title; or
(2) Meet or exceed the applicable particulate matter emission requirements of the Environmental Protection Administration listed in Table 57.5067-1, as follows:
Table 57.5067-1
(b) For purposes of paragraph (a):
(1) The term “introduced” means any engine added to the underground inventory of engines of the mine in question, including:
(i) An engine in newly purchased equipment;
(ii) An engine in used equipment brought into the mine; and
(iii) A replacement engine that has a different serial number than the engine it is replacing; but
(2) The term “introduced” does not include engines that were previously part of the mine inventory and rebuilt.
(3) The term introduced does not include the transfer of engines or equipment from the inventory of one underground mine to another underground mine operated by the same mine operator.
§ 57.6000 Definitions.
…plosives or blasting agents. Safety switch. A switch that provides shunt protection in blasting circuits between the blast site and the switch used to connect a power source to the blasting circuit. Slurry. An explosive material containing substantial portio…
The following definitions apply in this subpart.
Blasting agent. Any substance classified as a blasting agent by the Department of Transportation in 49 CFR 173.114a(a). This document is available at any MSHA Metal and Nonmetal Safety and Health district office.
Detonating cord. A flexible cord containing a center core of high explosives which may be used to initiate other explosives.
Detonator. Any device containing a detonating charge used to initiate an explosive. These devices include electronic detonators, electric or nonelectric instantaneous or delay blasting caps, and delay connectors. The term “detonator” does not include detonating cord. Detonators may be either “Class A” detonators or “Class C” detonators, as classified by the Department of Transportation in 49 CFR 173.53 and 173.100, which is available at any MSHA Metal and Nonmetal Safety and Health district office.
Explosive. Any substance classified as an explosive by the Department of Transportation in 49 CFR 173.53, 173.88, and 173.100. This document is available at any MSHA Metal and Nonmetal Safety and Health district office.
Explosive material. Explosives, blasting agents, and detonators.
Flash point. The minimum temperature at which sufficient vapor is released by a liquid to form a flammable vapor-air mixture near the surface of the liquid.
Igniter cord. A fuse that burns progressively along its length with an external flame at the zone of burning, used for lighting a series of safety fuses in a desired sequence.
Magazine. A bullet-resistant, theft-resistant, fire-resistant, weather-resistant, ventilated facility for the storage of explosives and detonators (BATF Type 1 or Type 2 facility).
Misfire. The complete or partial failure of explosive material to detonate as planned. The term also is used to describe the explosive material itself that has failed to detonate.
Primer. A unit, package, or cartridge of explosives which contains a detonator and is used to initiate other explosives or blasting agents.
Safety switch. A switch that provides shunt protection in blasting circuits between the blast site and the switch used to connect a power source to the blasting circuit.
Slurry. An explosive material containing substantial portions of a liquid, oxidizers, and fuel, plus a thickener.
Water gel. An explosive material containing substantial portions of water, oxidizers, and fuel, plus a cross-linking agent.
§ 57.6202 Vehicles.
…d in the cargo space; and (2) Provide any enclosed screw-type conveyors with protection against internal pressure and frictional heat.…
(a) Vehicles containing explosive material shall be—
(1) Maintained in good condition and shall comply with the requirements of subpart M of this part;
(2) Equipped with sides and enclosures higher than the explosive material being transported or have the explosive material secured to a nonconductive pallet;
(3) Equipped with a cargo space that shall contain the explosive material (passenger areas shall not be considered cargo space);
(4) Equipped with at least two multipurpose dry-chemical fire extinguishers or one such extinguisher and an automatic fire suppression system;
(5) Posted with warning signs that indicate the contents and are visible from each approach;
(6) Occupied only by persons necessary for handling the explosive material;
(7) Attended or the cargo compartment locked at surface areas of underground mines, except when parked at the blast site and loading is in progress; and
(8) Secured while parked by having—
(i) The brakes set;
(ii) The wheels chocked if movement could occur; and
(iii) The engine shut off unless powering a device being used in the loading operation.
(b) Vehicles containing explosives shall have—
(1) No sparking material exposed in the cargo space; and
(2) Only properly secured nonsparking equipment in the cargo space with the explosives.
(c) Vehicles used for dispensing bulk explosive material shall—
(1) Have no zinc or copper exposed in the cargo space; and
(2) Provide any enclosed screw-type conveyors with protection against internal pressure and frictional heat.
§ 57.6905 Protection of explosive material.
(a) Explosive material shall be protected from temperatures in excess of 150 degrees Fahrenheit. (b) Explosive material shall be protected from impact, except for tamping and dropping during loading.
(a) Explosive material shall be protected from temperatures in excess of 150 degrees Fahrenheit.
(b) Explosive material shall be protected from impact, except for tamping and dropping during loading.
§ 57.7803 Lighting the burner.
A suitable means of protection shall be provided for the employee when lighting the burner.…
A suitable means of protection shall be provided for the employee when lighting the burner.
§ 57.9302 Protection against moving or runaway railroad equipment.
Stopblocks, derail devices, or other devices that protect against moving or runaway rail equipment shall be installed wherever necessary to protect persons.
Stopblocks, derail devices, or other devices that protect against moving or runaway rail equipment shall be installed wherever necessary to protect persons.
§ 57.9362 Protection of signalmen.
Signalmen used during slushing operations underground shall be located away from possible contact with cables, sheaves, and slusher buckets.
Signalmen used during slushing operations underground shall be located away from possible contact with cables, sheaves, and slusher buckets.
§ 57.11012 Protection for openings around travelways.
Openings above, below, or near travelways through which persons or materials may fall shall be protected by railings, barriers, or covers. Where it is impractical to install such protective devices, adequate warning signals shall be installed.
Openings above, below, or near travelways through which persons or materials may fall shall be protected by railings, barriers, or covers. Where it is impractical to install such protective devices, adequate warning signals shall be installed.
§ 57.11059 Respirable atmosphere for hoist operators underground.
For the protection of operators of hoists located underground which are part of the mine escape and evacuation plan required under standard 57.11053, the hoist operator shall be provided with a respirable atmosphere completely independent of the mine atmospher…
For the protection of operators of hoists located underground which are part of the mine escape and evacuation plan required under standard 57.11053, the hoist operator shall be provided with a respirable atmosphere completely independent of the mine atmosphere. This independent ventilation system shall convert, without contamination, to an approved and properly maintained 2-hour self-contained breathing apparatus to provide a safe means of escape for the hoist operator after the hoisting duties have been completed as prescribed in the mine escape and evacuation plan for that hoist. The hoist operator's independent ventilation system shall be provided by one of the following methods:
(a) A suitable enclosure equipped with a positive pressure ventilation system which may be operated continuously or be capable of immediate activation from within the enclosure during an emergency evacuation. Air for the enclosure's ventilation system shall be provided in one of the following ways:
(1) Air coursed from the surface through a borehole into the hoist enclosure directly or through a metal pipeline from such borehole; or
(2) Air coursed from the surface through metal duct work into the hoist enclosure, although this duct work shall not be located in timber-supported active workings; or
(3) Air supplied by air compressors located on the surface and coursed through metal pipe into the hoist enclosure.
A back-up system shall be provided for a hoist enclosure ventilation system provided by either of the methods set forth in paragraphs (a) (2) and (3) of this section. This back-up system shall consist of compressed air stored in containers connected to the enclosure. This back-up system shall provide and maintain a respirable atmosphere in the enclosure for a period of time equal to at least twice the time necessary to complete the evacuation of all persons designated to use that hoist as prescribed in the mine escape and evacuation plan required under standard 57.11053; or
(b) An approved and properly maintained self-contained breathing apparatus system which shall consist of a mask connected to compressed air stored in containers adjacent to the hoist controls. The self-contained breathing system shall provide a minimum of 24 hours of respirable atmosphere to the hoist operator. In addition, the self-contained breathing system shall be capable of a quick connect with the approved 2-hour self-contained breathing apparatus above.
§ 57.12001 Circuit overload protection.
Circuits shall be protected against excessive overloads by fuses or circuit breakers of the correct type and capacity.
Circuits shall be protected against excessive overloads by fuses or circuit breakers of the correct type and capacity.
§ 57.12005 Protection of power conductors from mobile equipment.
Mobile equipment shall not run over power conductors, nor shall loads be dragged over power conductors, unless the conductors are properly bridged or protected.
Mobile equipment shall not run over power conductors, nor shall loads be dragged over power conductors, unless the conductors are properly bridged or protected.
§ 57.12013 Splices and repairs of power cables.
…hat of the original, and sealed to exclude moisture; and, (c) Provided with damage protection as near as possible to that of the original, including good bonding to the outer jacket.…
Permanent splices and repairs made in power cables, including the ground conductor where provided, shall be—
(a) Mechanically strong with electrical conductivity as near as possible to that of the original;
(b) Insulated to a degree at least equal to that of the original, and sealed to exclude moisture; and,
(c) Provided with damage protection as near as possible to that of the original, including good bonding to the outer jacket.
§ 57.12014 Handling energized power cables.
…oved manually, insulated hooks, tongs, ropes, or slings shall be used unless suitable protection for persons is provided by other means. This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is physically attached to the…
Power cables energized to potentials in excess of 150 volts, phase-to-ground, shall not be moved with equipment unless sleds or slings, insulated from such equipment, are used. When such energized cables are moved manually, insulated hooks, tongs, ropes, or slings shall be used unless suitable protection for persons is provided by other means. This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is physically attached to the equipment by suitable mechanical devices, and the cable is insulated from the equipment in conformance with other standards in this part.
§ 57.12020 Protection of persons at switchgear.
Dry wooden platforms, insulating mats, or other electrically-nonconductive material shall be kept in place at all switchboards and power-control switches where shock hazards exist. However, metal plates on which a person normally would stand and which are kept…
Dry wooden platforms, insulating mats, or other electrically-nonconductive material shall be kept in place at all switchboards and power-control switches where shock hazards exist. However, metal plates on which a person normally would stand and which are kept at the same potential as the grounded, metal, non-current-carrying parts of the power switches to be operated may be used.
§ 57.12023 Guarding electrical connections and resistor grids.
…resistor grids that are difficult or impractical to insulate shall be guarded, unless protection is provided by location.…
Electrical connections and resistor grids that are difficult or impractical to insulate shall be guarded, unless protection is provided by location.
§ 57.12025 Grounding circuit enclosures.
…closing or encasing electrical circuits shall be grounded or provided with equivalent protection. This requirement does not apply to battery-operated equipment.…
All metal enclosing or encasing electrical circuits shall be grounded or provided with equivalent protection. This requirement does not apply to battery-operated equipment.
§ 57.12027 Grounding mobile equipment.
Frame grounding or equivalent protection shall be provided for mobile equipment powered through trailing cables.…
Frame grounding or equivalent protection shall be provided for mobile equipment powered through trailing cables.
§ 57.12039 Protection of surplus trailing cables.
Surplus trailing cables to shovels, cranes and similar equipment shall be— (a) Stored in cable boats; (b) Stored on reels mounted on the equipment; or (c) Otherwise protected from mechanical damage.
Surplus trailing cables to shovels, cranes and similar equipment shall be—
(a) Stored in cable boats;
(b) Stored on reels mounted on the equipment; or
(c) Otherwise protected from mechanical damage.
§ 57.12065 Short circuit and lightning protection.
Powerlines, including trolley wires, and telephone circuits shall be protected against short circuits and lightning.
Powerlines, including trolley wires, and telephone circuits shall be protected against short circuits and lightning.
§ 57.12069 Lightning protection for telephone wires and ungrounded conductors.
Each ungrounded conductor or telephone wire that leads underground and is directly exposed to lightning shall be equipped with suitable lightning arrestors of approved type within 100 feet of the point where the circuit enters the mine. Lightning arrestors sha…
Each ungrounded conductor or telephone wire that leads underground and is directly exposed to lightning shall be equipped with suitable lightning arrestors of approved type within 100 feet of the point where the circuit enters the mine. Lightning arrestors shall be connected to a low resistance grounding medium on the surface and shall be separated from neutral grounds by a distance of not less than 25 feet.
§ 57.14106 Falling object protection.
(a) Fork-lift trucks, front-end loaders, and bulldozers shall be provided with falling object protective structures if used in an area where falling objects could create a hazard to the operator. (b) The protective structure shall be capable of withstanding t…
(a) Fork-lift trucks, front-end loaders, and bulldozers shall be provided with falling object protective structures if used in an area where falling objects could create a hazard to the operator.
(b) The protective structure shall be capable of withstanding the falling object loads to which it could be subjected.
§ 57.14110 Flying or falling materials.
…ushers, or conveyors present a hazard, guards, shields, or other devices that provide protection against such flying or falling materials shall be provided to protect persons.…
In areas where flying or falling materials generated from the operation of screens, crushers, or conveyors present a hazard, guards, shields, or other devices that provide protection against such flying or falling materials shall be provided to protect persons.
§ 57.15004 Eye protection.
All persons shall wear safety glasses, goggles, or face shields or other suitable protective devices when in or around an area of a mine or plant where a hazard exists which could cause injury to unprotected eyes.
All persons shall wear safety glasses, goggles, or face shields or other suitable protective devices when in or around an area of a mine or plant where a hazard exists which could cause injury to unprotected eyes.
§ 57.15014 Eye protection when operating grinding wheels.
Face shields or goggles in good condition shall be worn when operating a grinding wheel.
Face shields or goggles in good condition shall be worn when operating a grinding wheel.
§ 57.12047 Guy wires.
…igh-voltage transmission lines shall meet the requirements for grounding or insulator protection of the National Electrical Safety Code, part 2, entitled “Safety Rules for the Installation and Maintenance of Electric Supply and Communication Lines” (also refer…
Guy wires of poles supporting high-voltage transmission lines shall meet the requirements for grounding or insulator protection of the National Electrical Safety Code, part 2, entitled “Safety Rules for the Installation and Maintenance of Electric Supply and Communication Lines” (also referred to as National Bureau of Standards Handbook 81, Nov. 1, 1961), and Supplement 2 thereof issued March 1968, which are hereby incorporated by reference and made a part hereof. These publications and documents may be obtained from the National Institute of Science and Technology, 100 Bureau Drive, Stop 3460, Gaithersburg, MD 20899-3460. Telephone: 301-975-6478 (not a toll free number); http://ts.nist.gov/nvl; or from the Government Printing Office, Information Dissemination (Superintendent of Documents), P.O. Box 371954, Pittsburgh, PA 15250-7954; Telephone: 866-512-1800 (toll free) or 202-512-1800; http://bookstore.gpo.gov, or may be examined in any Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration.
§ 57.16006 Protection of gas cylinder valves.
Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.
Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.
§ 57.19014 Friction hoist overtravel protection.
In a friction hoist installation, tapered guides or other approved devices shall be installed above and below the limits of regular travel of the conveyance and arranged to prevent overtravel in the event of failure of other devices.
In a friction hoist installation, tapered guides or other approved devices shall be installed above and below the limits of regular travel of the conveyance and arranged to prevent overtravel in the event of failure of other devices.
§ 57.19050 Bucket requirements.
…rection between the lower and upper crosshead parking locations; (b) Have overhead protection when the shaft depth exceeds 50 feet; (c) Have sufficient depth or a suitably designed platform to transport persons safely in a standing position; and (d) Have de…
Buckets used to hoist persons during vertical shaft sinking operations shall—
(a) Be securely attached to a crosshead when traveling in either direction between the lower and upper crosshead parking locations;
(b) Have overhead protection when the shaft depth exceeds 50 feet;
(c) Have sufficient depth or a suitably designed platform to transport persons safely in a standing position; and
(d) Have devices to prevent accidental dumping where the bucket is supported by a bail attached to its lower half.
§ 57.19074 Riding the bail, rim, bonnet, or crosshead.
…nce except when necessary for inspection and maintenance, and then only when suitable protection for persons is provided.…
Persons shall not ride the bail, rim, bonnet, or crosshead of any shaft conveyance except when necessary for inspection and maintenance, and then only when suitable protection for persons is provided.
Convenience copy of public-domain federal regulations, synced from the official eCFR on Sep 6, 2026. Not legal authority — verify anything that matters against eCFR.gov and current MSHA guidance.